首页 -> 调节阀 -> HDP 压力先导式调节阀 [1] [2] 
 D-系列尺寸表 - 英寸/磅
  端面间距   重量(磅)
尺寸 NPT/BSP 125# 250# B C* D E** NPT/BSP 法兰
1/2" 5-1/8     5-1/8 11 5-7/8 7 18  
3/4" 5-1/2     5-1/2 11 6-1/2 7-1/4 21  
1" 6-1/8     6-1/8 11 7 7-1/2 25  
1-1/4" 8-1/2     7 11-7/8 8-3/4 8 45  
1-1/2" 9-1/2     7-1/8 11-7/8 8-3/4 8-1/2 55  
2" 9-3/4 9-1/2 9-5/8 7-1/8 11-7/8 10-7/8 9 90 105
2-1/2"   10 10-5/8 8-3/4 11-7/8 11-3/4 9-1/2   135
3"   11 11-3/4 9-1/8 11-7/8 13-1/4 10   180
4"   13-3/8 13-7/8 10-3/8 11-7/8 14-3/4 11   290
6"   18-1/8 19 16 12-1/2 19-3/4 12   590
 HD-系列尺寸表 - 英寸/磅
  端面间距   重量(磅)
尺寸 NPT/BSP 150# 300# B C* D E** NPT/BSP 法兰
1/2" 4-3/8     5-1/2 11-7/8 6-1/2 7-3/4 18  
3/4" 4-3/8     5-1/2 11-7/8 6-1/2 7-3/4 18  
1" 5-3/8     6-1/4 11-7/8 7 7-3/4 23  
1-1/4" 7-1/4     7-3/8 11-7/8 8-3/4 8-1/4 43  
1-1/2" 7-1/4     7-3/8 11-7/8 8-3/4 8-1/4 43  
2" 7-1/2 8-1/2 9 8-1/4 11-7/8 10-7/8 8-1/2 65 85
2-1/2"   9-3/8 10 9 11-7/8 11-3/4 8-1/2   105
3"   10 10-3/4 8-7/8 11-7/8 13-1/4 9-1/2   145
4"   11-7/8 12-1/2 10-7/8 11-7/8 14-3/4 10-1/2   235
6"   15-1/8 16 14-1/8 12-1/2 19-3/4 11-3/4   470
*P5型先导阀:对于尺寸1/2”~1-1/2”,C栏尺寸另加2-1/2’;
对于尺寸2”~6”,C栏尺寸另加5”。
**P5型先导阀:对于所有尺寸,E栏尺寸均另加1-1/2”。
 
选型和下定单
“P”型或“P5”压力先导阀
请标明:减压范围
调节阀
请标明:
      D系列或HD系列调节阀
      调节阀接口尺寸或蒸汽流量及压力
      接口尺寸(BSPT或NPT 螺口,PN16 / 125# / 150# / 250# / 300# 法兰)
 
工作原理
    安装压力先导阀用以控制压力先导式减压阀的操作工况。连接在先导阀与减压阀下游管线上的反馈管可反馈压力变化情况。反馈管的压力变化直接作用于先导阀的膜片下。当系统压力达到调节弹簧的压力设定点时,膜片下的压力推动其压紧弹簧向上移动,逐步关闭压力先导阀,当压力先导阀关闭,蒸汽不会再进入减压阀主阀下面的隔膜腔,主阀也随之关闭。当蒸汽压力下降低于其设定值,压力先导阀打开,蒸汽进入主阀隔膜腔,顶起主膜片打开主阀。